How To Wire Npn Sensor To Plc

How To Wire Npn Sensor To Plc. To wire our pnp proximity sensor, you can use this methodology. What this means is that plcs will read high at the input side only when the voltage is at 24 volts dc.

Difference between PNP and NPN sensor Sensor
Difference between PNP and NPN sensor Sensor from www.pinterest.se

The black wire of our sensor is connected to the plc input. Can this sensor output be converted to pnp type by connecting a pullup resistor (tied to +24 vdc) ? But the signal output wire of proximity sensor must be connected to the signal input point of plc, so when a npn proximity sensor is connected, the signal flows from the input signal terminal of plc, and the other end of load (namely the common port com) shall be connected to the high level (namely the 24v+).

In This Video, We're Going To Talk About Sinking And Sourcing Plc Digital Input Modules With Pnp & Npn Sensors And How To Wire About Video Source And Sink Type Connection, Plc Programming, Source Sink Connection With Sensors, Source And Sink In Plc, This Video Shows The Link Between Types Of Sensors (Npn Pnp) And Types Of Plc Input Cards.


We will now look at wiring an npn and pnp inductive proximity sensor to the click plc. The +v (brown) will be attached to the common input and the switching wire (black) will be attached to the input number. Then attach wire 2 (blue wire), to the common terminal on the power supply.

We Will Show The Wiring Of An Npn Sensor Into A Plc.


Our sensor output when turned on will allow conventional current to flow +. The magnetic pickup sensor is from dart controls. We will replace the sinking plc input contact that we have shown above with a pnp sensor.

These Discrete Sensors Have Internal Switching Circuits That Classify Them As Either A Sinking (Npn) Or A Sourcing Device (Pnp).


The sensor output is wired to the input point of the plc. The blue wire of our sensor is connected to the 0vdc supply. What this means is that plcs will read high at the input side only when the voltage is at 24 volts dc.

Can This Sensor Output Be Converted To Pnp Type By Connecting A Pullup Resistor (Tied To +24 Vdc) ?


When connecting to the plc, the plc input acts as the load. P np = switched p ositive. But the signal output wire of proximity sensor must be connected to the signal input point of plc, so when a npn proximity sensor is connected, the signal flows from the input signal terminal of plc, and the other end of load (namely the common port com) shall be connected to the high level (namely the 24v+).

In This Video Explain How To Connect Pnp Npn Sensor In Plc Inputwiring Npn And Pnp Sensors Into The Plcdelta Dvp Plc Input Npn & Pnp Wiringwhat Is The Differ.


The common point of the plc input is connected to the 0vdc supply and the black wire of our sensor is connected to the plc input. You can see that when the proximity switches, the sensor then connects the load to 24vdc. “switched” refers to which side of the controlled load (relay, small indicator, plc input) is being switched electrically.